{"title":"Aspirating smoke detection (VENTUM)","description":"\u003cp\u003ePOLON-ALFA VENTUM aspirating smoke detection: LITE, PRO LITE, PRO, PRO|net and PRO MAX detectors, detection modules, Ethernet modules, filters, pipe purge system, ABS \/ PVC pipework and accessories for very early fire detection.\u003c\/p\u003e","products":[{"product_id":"polon-alfa-ventum-pro","title":"VENTUM PRO - aspirating smoke detector (housing — standard \/ Deep-Freeze \/ Silent)","description":"\u003cul class=\"keypoints\"\u003e\n\u003cli\u003eAspirating smoke detector for very early detection\u003c\/li\u003e\n\u003cli\u003e1 or 2 DM-VP detection modules — sensitivity 0.5 \/ 0.1 \/ 0.015 % obsc.\/m\u003c\/li\u003e\n\u003cli\u003eVersions: standard, Deep-Freeze (for deep-freeze chambers) and Silent (low noise)\u003c\/li\u003e\n\u003cli\u003eDetection module, front foil and pipework are ordered separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVENTUM PRO\u003c\/strong\u003e — housing of the POLON-ALFA aspirating smoke detector. The aspirating system continuously draws an air sample from the protected space through a pipe with sampling holes and delivers it to the central detection module, which detects even the smallest concentration of smoke — long before any visible smoke appears.\u003c\/p\u003e\u003cp\u003eOne or two DM-VP detection modules of the required sensitivity are installed in the housing. The Deep-Freeze version is intended for deep-freeze warehouses and cold rooms, the Silent version for noise-sensitive spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eServer rooms and data centres\u003c\/li\u003e\n\u003cli\u003eHigh-bay halls and warehouses\u003c\/li\u003e\n\u003cli\u003eCold rooms and deep-freeze chambers (Deep-Freeze)\u003c\/li\u003e\n\u003cli\u003eSpaces where servicing point detectors is difficult\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable class=\"specs\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eVENTUM (POLON-ALFA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVENTUM PRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersions\u003c\/td\u003e\n\u003ctd\u003eVP-1 standard, VP-1-F Deep-Freeze, VP-1-SL Silent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection modules\u003c\/td\u003e\n\u003ctd\u003e1 or 2 — DM-VP-50 \/ DM-VP-10 \/ DM-VP-01 (-F versions for Deep-Freeze), ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity (depending on module)\u003c\/td\u003e\n\u003ctd\u003e0,5 \/ 0,1 \/ 0,015 % obsc.\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront foil\u003c\/td\u003e\n\u003ctd\u003eFP-VP-1 (1 module) \/ FP-VP-2 (2 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilters (optional)\u003c\/td\u003e\n\u003ctd\u003eLF-VE \/ LF-VE-1 \/ LF-VE-2, SF-400 \/ SF-650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipework\u003c\/td\u003e\n\u003ctd\u003eABS 25 mm or PVC 25 \/ 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eModels (3)\u003c\/h3\u003e\u003ctable class=\"specs models\"\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVP-1\u003c\/td\u003e\n\u003ctd\u003eStandard (code VE-05-0457)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVP-1-F\u003c\/td\u003e\n\u003ctd\u003eDeep-Freeze (code VE-05-0467)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVP-1-SL\u003c\/td\u003e\n\u003ctd\u003eSilent (code VE-05-0458)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eThe detailed VENTUM technical datasheet (pipe length, number of sampling holes, power supply and current consumption) and the project calculation are available on request from an AXIA specialist.\u003c\/p\u003e\u003cp class=\"source\"\u003eManufacturer: POLON-ALFA (Poland).\u003c\/p\u003e","brand":"POLON-ALFA","offers":[{"title":"VP-1 · Standard","offer_id":68021542027630,"sku":"VP-1","price":0.0,"currency_code":"GEL","in_stock":true},{"title":"VP-1-F · Deep-Freeze","offer_id":68021542060398,"sku":"VP-1-F","price":0.0,"currency_code":"GEL","in_stock":true},{"title":"VP-1-SL · Silent","offer_id":68021542093166,"sku":"VP-1-SL","price":0.0,"currency_code":"GEL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1024\/4495\/8062\/files\/axia-ventum-pro.jpg?v=1794163697"},{"product_id":"polon-alfa-ventum-pro-lite","title":"VENTUM PRO LITE - aspirating smoke detector (housing — standard \/ Silent)","description":"\u003cul class=\"keypoints\"\u003e\n\u003cli\u003eAspirating smoke detector of the PRO LITE series\u003c\/li\u003e\n\u003cli\u003e1 or 2 DM-VPL detection modules — sensitivity 0.5 \/ 0.1 \/ 0.015 % obsc.\/m\u003c\/li\u003e\n\u003cli\u003eVersions: standard and Silent (low noise)\u003c\/li\u003e\n\u003cli\u003eDetection module, front foil and pipework are ordered separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVENTUM PRO LITE\u003c\/strong\u003e — housing of an aspirating smoke detector. The system continuously draws air from the protected space through a pipe with sampling holes and analyses it in the detection module, which allows a fire to be detected at a very early stage.\u003c\/p\u003e\u003cp\u003eOne or two DM-VPL detection modules are installed in the housing. The Silent version is intended for spaces where fan noise must be kept to a minimum.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eServer and technical rooms\u003c\/li\u003e\n\u003cli\u003eOffices, archives and museums\u003c\/li\u003e\n\u003cli\u003eSpaces where installing or servicing point detectors is difficult\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable class=\"specs\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eVENTUM (POLON-ALFA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVENTUM PRO LITE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersions\u003c\/td\u003e\n\u003ctd\u003eVPL-1 standard, VPL-1-SL Silent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection modules\u003c\/td\u003e\n\u003ctd\u003e1 or 2 — DM-VPL-50 \/ DM-VPL-10 \/ DM-VPL-01, ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity (depending on module)\u003c\/td\u003e\n\u003ctd\u003e0,5 \/ 0,1 \/ 0,015 % obsc.\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront foil\u003c\/td\u003e\n\u003ctd\u003eFP-VPL-1 (1 module) \/ FP-VPL-2 (2 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilters (optional)\u003c\/td\u003e\n\u003ctd\u003eLF-VE \/ LF-VE-1 \/ LF-VE-2, SF-400 \/ SF-650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipework\u003c\/td\u003e\n\u003ctd\u003eABS 25 mm or PVC 25 \/ 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eModels (2)\u003c\/h3\u003e\u003ctable class=\"specs models\"\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPL-1\u003c\/td\u003e\n\u003ctd\u003eStandard (code VE-05-1140)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPL-1-SL\u003c\/td\u003e\n\u003ctd\u003eSilent (code VE-05-1145)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eThe detailed VENTUM technical datasheet (pipe length, number of sampling holes, power supply and current consumption) and the project calculation are available on request from an AXIA specialist.\u003c\/p\u003e\u003cp class=\"source\"\u003eManufacturer: POLON-ALFA (Poland).\u003c\/p\u003e","brand":"POLON-ALFA","offers":[{"title":"VPL-1 · Standard","offer_id":68021542125934,"sku":"VPL-1","price":0.0,"currency_code":"GEL","in_stock":true},{"title":"VPL-1-SL · Silent","offer_id":68021542158702,"sku":"VPL-1-SL","price":0.0,"currency_code":"GEL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1024\/4495\/8062\/files\/axia-ventum-pro-lite.jpg?v=1794163697"},{"product_id":"polon-alfa-ventum-pro-max","title":"VENTUM PRO MAX - aspirating smoke detector (housing — standard \/ Deep-Freeze \/ Silent)","description":"\u003cul class=\"keypoints\"\u003e\n\u003cli\u003eTop-of-the-range aspirating smoke detector of the VENTUM family\u003c\/li\u003e\n\u003cli\u003e1 or 2 DM-VN detection modules — sensitivity 0.5 \/ 0.1 \/ 0.015 % obsc.\/m\u003c\/li\u003e\n\u003cli\u003eVersions: standard, Deep-Freeze and Silent\u003c\/li\u003e\n\u003cli\u003eBMS \/ SMS integration via the NU-5 Ethernet module (SNMP), event logging to an SD card\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVENTUM PRO MAX\u003c\/strong\u003e — housing of the top-of-the-range aspirating smoke detector of the VENTUM series. The system continuously draws air from the protected space through a pipe with sampling holes and detects smoke at a very early stage of a fire.\u003c\/p\u003e\u003cp\u003eOne or two DM-VN detection modules are installed in the housing. With the NU-5 Ethernet module, the detector can be connected to a building management system (BMS) or security management system (SMS) using the open SNMP protocol; the NU-5-D version stores events on a 1 GB SD card.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eData centres and critical IT infrastructure\u003c\/li\u003e\n\u003cli\u003eLarge warehouses and high-bay halls\u003c\/li\u003e\n\u003cli\u003eCold rooms and deep-freeze chambers (Deep-Freeze)\u003c\/li\u003e\n\u003cli\u003eSites with BMS \/ SMS monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable class=\"specs\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eVENTUM (POLON-ALFA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVENTUM PRO MAX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersions\u003c\/td\u003e\n\u003ctd\u003eVMN-1 standard, VMN-1-F Deep-Freeze, VMN-1-SL Silent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection modules\u003c\/td\u003e\n\u003ctd\u003e1 or 2 — DM-VN-50 \/ DM-VN-10 \/ DM-VN-01 (-F versions for Deep-Freeze), ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity (depending on module)\u003c\/td\u003e\n\u003ctd\u003e0,5 \/ 0,1 \/ 0,015 % obsc.\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegration (optional)\u003c\/td\u003e\n\u003ctd\u003eEthernet module NU-5 \/ NU-5-D \/ NU-5-D-F — SNMP, BMS \/ SMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront foil\u003c\/td\u003e\n\u003ctd\u003eFP-VMN-1 (1 module) \/ FP-VMN-2 (2 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilters (optional)\u003c\/td\u003e\n\u003ctd\u003eLF-VE \/ LF-VE-1 \/ LF-VE-2, SF-400 \/ SF-650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipework\u003c\/td\u003e\n\u003ctd\u003eABS 25 mm or PVC 25 \/ 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eModels (3)\u003c\/h3\u003e\u003ctable class=\"specs models\"\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVMN-1\u003c\/td\u003e\n\u003ctd\u003eStandard (code VE-05-1220)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVMN-1-F\u003c\/td\u003e\n\u003ctd\u003eDeep-Freeze (code VE-05-1350)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVMN-1-SL\u003c\/td\u003e\n\u003ctd\u003eSilent (code VE-05-1240)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eThe detailed VENTUM technical datasheet (pipe length, number of sampling holes, power supply and current consumption) and the project calculation are available on request from an AXIA specialist.\u003c\/p\u003e\u003cp class=\"source\"\u003eManufacturer: POLON-ALFA (Poland).\u003c\/p\u003e","brand":"POLON-ALFA","offers":[{"title":"VMN-1 · Standard","offer_id":68021542289774,"sku":"VMN-1","price":0.0,"currency_code":"GEL","in_stock":true},{"title":"VMN-1-F · Deep-Freeze","offer_id":68021542322542,"sku":"VMN-1-F","price":0.0,"currency_code":"GEL","in_stock":true},{"title":"VMN-1-SL · Silent","offer_id":68021542355310,"sku":"VMN-1-SL","price":0.0,"currency_code":"GEL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1024\/4495\/8062\/files\/axia-ventum-pro-max.jpg?v=1794163697"},{"product_id":"polon-alfa-ventum-lite","title":"VENTUM LITE - aspirating smoke detector (HB-VL housing and DM-VL-50 detection module)","description":"\u003cul class=\"keypoints\"\u003e\n\u003cli\u003eVENTUM LITE compact aspirating smoke detector\u003c\/li\u003e\n\u003cli\u003eConsists of the HB-VL housing and the DM-VL-50 detection module (0.5 % obsc.\/m)\u003c\/li\u003e\n\u003cli\u003eReplaceable internal filter insert SP-VL-5\u003c\/li\u003e\n\u003cli\u003eBMS \/ SMS integration via the NU-2 Ethernet module in the AB-1 housing\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVENTUM LITE\u003c\/strong\u003e — compact aspirating smoke detector for small and medium-sized spaces. An air sample from the protected space is delivered through a pipe to the detection module, which detects smoke earlier than a point detector.\u003c\/p\u003e\u003cp\u003eBoth elements are required for a complete detector: the HB-VL housing and the DM-VL-50 detection module. The NU-2 Ethernet module, installed in the AB-1 accessory housing, is used for network connection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eServer and electrical rooms\u003c\/li\u003e\n\u003cli\u003eCabinets and technical niches\u003c\/li\u003e\n\u003cli\u003eSmall archives and storerooms\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable class=\"specs\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eVENTUM (POLON-ALFA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVENTUM LITE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet\u003c\/td\u003e\n\u003ctd\u003eHB-VL housing + DM-VL-50 detection module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e0,5 % obsc.\/m (DM-VL-50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal filter\u003c\/td\u003e\n\u003ctd\u003eReplaceable insert SP-VL-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront foil\u003c\/td\u003e\n\u003ctd\u003eFP-VL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegration (optional)\u003c\/td\u003e\n\u003ctd\u003eEthernet module NU-2 \/ NU-2-D \/ NU-2-D-F in the AB-1 housing — SNMP, BMS \/ SMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eModels (2)\u003c\/h3\u003e\u003ctable class=\"specs models\"\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB-VL\u003c\/td\u003e\n\u003ctd\u003eDetector housing (code VE-05-3500)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDM-VL-50\u003c\/td\u003e\n\u003ctd\u003eDetection module, 0.5 % obsc.\/m (code VE-05-4531)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eThe detailed VENTUM technical datasheet (pipe length, number of sampling holes, power supply and current consumption) and the project calculation are available on request from an AXIA specialist.\u003c\/p\u003e\u003cp class=\"source\"\u003eManufacturer: POLON-ALFA (Poland).\u003c\/p\u003e","brand":"POLON-ALFA","offers":[{"title":"HB-VL · Detector housing","offer_id":68021550743918,"sku":"HB-VL","price":0.0,"currency_code":"GEL","in_stock":true},{"title":"DM-VL-50 · Detection module, 0.5 % obsc.\/m","offer_id":68021550776686,"sku":"DM-VL-50","price":0.0,"currency_code":"GEL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1024\/4495\/8062\/files\/axia-ventum-lite.jpg?v=1794163697"}],"url":"https:\/\/axia.ge\/en\/collections\/aspirating-smoke-detection\/%e1%83%90%e1%83%a1%e1%83%9e%e1%83%98%e1%83%a0%e1%83%90%e1%83%aa%e1%83%98%e1%83%a3%e1%83%9a%e1%83%98-%e1%83%93%e1%83%94%e1%83%a2%e1%83%94%e1%83%a5%e1%83%a2%e1%83%9d%e1%83%a0%e1%83%98.oembed","provider":"AXIA","version":"1.0","type":"link"}